Products
Explosion-proof fixed thread thermocouple
- Product Description
-
Explosion-proof fixed thread thermocouple
1. Explosion-proof fixed thread-type thermocouple - applications
Explosion-proof thermocouples are usually used in conjunction with display instruments, recorders, electronic computing, and similar devices. Directly measures the surface temperature of liquids, vapors, gases, and solids in the 0°C~1300°C range for explosives such as hydrocarbons at the production site.
2. Features of explosion-proof fixed threaded thermocouples
Multiple explosion-proof types, excellent explosion-proof performance, spring-type temperature sensing elements, excellent vibration resistance, wide temperature measurement range, high mechanical strength, and good pressure resistance
3. Explosion-Proof Fixed Thread Thermocouple - Working Principle
Explosion-proof thermocouples utilize the explosion-proof principle of gaps, designed with sufficiently strong junction boxes and other components. All components that may generate sparks, arcs, or hazardous temperatures are sealed inside the junction box chamber. When an explosion occurs inside the chamber, the flame can be extinguished and cooled through the gap at the joint surface, preventing the flame and temperature from passing outside the chamber, thus providing explosion protection.
4. Explosion-proof fixed threaded thermocouple - selection table
Product models
Degree number
Temperature range: °C
Thermal response time
Protective tube materials
Specifications (mm)
d
L x l
WRM-240
WRM2-240
N
0-800
<90S
1Cr18Ni9Ti
φ16
300x150
350x200
400x250
450x300
550x400
650x500
900x750
1150x1000
1650x1500
2150x2000
0-1000
0Cr25Ni20
WRM-240G
WRM2-240G
0-800
<24S
1Cr18Ni9Ti
0-1000
0Cr25Ni20
WRN-240
WRN2-240
K
0-800
<90S
1Cr18Ni9Ti
0-1000
0Cr25Ni20
WRN-240G
WRN2-240G
0-800
<24S
1Cr18Ni9Ti
0-1000
0Cr25Ni20
WRE-240
WRE2-240
E
0-700
<90S
1Cr18Ni9Ti
WRE-240G
WRE2-240G
<24S
WRC-240
WRC2-240
T
0-350
<90S
1Cr18Ni9Ti
WRC-240G
WRC2-240G
<24S
WRF-240
WRF2-240
J
0-600
<90S
1Cr18Ni9Ti
WRF-240G
WRF2-240G
<24S
(1) Thermocouple Class I and Grade A RTDs must be ordered according to agreement;
(2) Temperature measurement range and protective tube material not specified: The protective tube material is uniformly regarded as 1Cr18Ni9Ti;
(3) Other relevant technical parameter requirements can be ordered according to user agreements; Such as length, connection method, single or double pieces, etc