Prefabricated thermocouples
+
  • Prefabricated thermocouples

Prefabricated thermocouples

Industrial prefabricated thermocouples are commonly used as transmitters for temperature measurement, along with display instruments, recorders, and electronic regulators. It can directly measure the surface temperatures of liquids, vapors, and gases in various production processes ranging from 0C to 1800C,

Classification:

  • Product Description
  • Overview

    Industrial prefabricated thermocouples are commonly used as transmitters for temperature measurement, along with display instruments, recorders, and electronic regulators. It can directly measure the surface temperatures of liquids, vapors, and gases in various production processes ranging from 0°C to 1800°C, as well as solids.

    According to national regulations, our company produces prefabricated thermocouples such as platinum-rhodium 30-platinum-rhodium 6, platinum-rhodium 10-platinum, nickel-chromium-nickelsilicon, nickel-chromium-constant-copper, and other materials that comply with IEC international standard grading numbers.

    Assembled thermocouples usually consist of key components such as temperature sensing elements, mounting fixtures, and junction boxes.

    Available models (Type B, S, K, E)

    Thermocouple categoryCodenameDegree numberMeasurement rangeBasic error limit
    Nickel-Chromium-Con-CopperWRKE0-800℃±0.75%t
    Nickel-Chromium-Nickel SiliconWRNK0-1300℃±0.75%t
    Platinum rhodium13- PlatinumWRBR0-1600℃±0.25%t
    Platinum rhodium10- PlatinumWRPS0-1600℃±0.25%t
    Platinum rhodium30- Platinum rhodium6WRRB0-1800℃±0.25%t

    Main technical parameters

    Measurement range and basic error limits

    Note: t is the measured temperature value of the sensing element (°C).

    Thermocouple time constant

    Thermal inertness levelTime constant (seconds)Thermal inertness levelTime constant (seconds)

    90-180

    10-30

    30-90

    <10

    ◆ Nominal pressure of the thermocouple: generally refers to the static external pressure that the protective tube can withstand at operating temperature to cause rupture.

    ◆ Minimum thermocouple insertion depth: should not be less than 8-10 times the outer diameter of the protective sleeve (except for Telie products)

    ◆ Insulation resistance: When the ambient air temperature is 15-35°C and relative humidity is < 80%, the insulation resistance is ≥5 megaohms (voltage 100V). Thermocouples with splash-proof junction boxes, insulation resistance ≥ 0.5 megaohms (voltage 100V) at a relative temperature of 93±3°C.

    ◆ Insulation resistance at high temperatures: At high temperatures, the insulation resistance (per meter) between the thermocouple (including double-supported types), the protective tube, and the double-supported thermoelectric electrode should be greater than the values specified in the table below.


    Specified long-term operating temperature (°C)

    Specified long-term operating temperature (°C)

    Test temperature (°C)

    Insulation Resistance Value (Ω)

      ≥60060072000
      ≥ 80080025000
      ≥100010005000


    Thermocouples without fixed devices, fixed threaded thermocouples, movable flange thermocouples

    Fixed flange thermocouple, loop tube joint thermocouple, fixed threaded conical thermocouple

    Straight tube joint thermocouple, fixed threaded joint thermocouple, movable threaded tube joint thermocouple

Product Inquiry

Please leave your information, and we will contact you as soon as possible after receiving it. Thank you for your support!

Prefabricated thermocouples

It is committed to providing solutions for the high and low temperature all-in-one machine and industrial instrument industry